Move, then hold
Quasi-static control supports non-periodic motion, slow ramps, region-of-interest scans and point-to-point stepping.

Single-axis synchronized mirror and actuator arrays for deterministic positioning, stable holds and step-and-settle scanning.
Application-specific configuration
QSM-1D has a synchronized mirror array driven by a separate synchronized actuator array. Unlike the resonant mirror–actuator units used in IFM and ISM, these two arrays can differ in size: several actuator units can drive one mirror element. Small mirrors reduce rotational inertia, while combined actuator force supports the design goals of low-voltage positioning, fast response and stable holds. An actuator array can also drive a single larger mirror when the application calls for it.
Quasi-static control supports non-periodic motion, slow ramps, region-of-interest scans and point-to-point stepping.
Size mirror and actuator arrays separately to balance optical aperture and available actuation force.
Optional angle sensing supports closed-loop control. Aperture and coatings can be configured for visible or infrared applications.
Explore QSM-1D through device and optical demonstrations. Refer to the technical overview below for specifications and development status.
View specifications ↓Four synchronized mirrors, each driven by eight synchronized comb actuators, demonstrate smooth tilt followed by point-to-point stepping. This is the published demonstration configuration, not a fixed requirement for every QSM-1D device.
Visual demonstration · No audioA red laser illuminates the QSM-1D mirror, and the reflected spot moves across a paper screen behind the device. This original demonstration makes the steering response visible using the same eight-actuator-per-mirror configuration. The footage illustrates motion rather than a numerical settling-time or positioning measurement.
Visual demonstration · No audioDeterministic angle control supports step-and-repeat positioning, selected-region scans and slow ramps. These are application examples to scope around your optical system.
Slow-axis scanning for confocal and multiphoton imaging, beam placement for optical coherence tomography (OCT), light-sheet positioning, fiber coupling and laser-therapy alignment.
Region-of-interest scanning, beam pointing, boresight alignment and calibration during operation.
Optical metrology, spectrometer coupling, probe alignment and stabilization loops.
QSM-1D is a general-purpose building block for optical benches and integrated systems. Share your scan pattern, travel range and thermal envelope so we can scope the mirror and actuation under NDA.
Synchronize multiple actuator units to drive one mirror element when the application calls for higher torque or lower drive voltage. The eight-to-one mapping in the videos is one example.
Use matched actuator and mirror elements for modular scaling across an optical line.
Pair QSM-1D as the slow or positioning axis with a resonant fast-axis scanner to form a two-dimensional system.
The published demonstration illustrates an eight-to-one actuator-to-mirror mapping. No standardized numerical performance table is published; requirements should be discussed for the intended configuration.
| Parameter | Value / notes |
|---|---|
| Motion | Single-axis, quasi-static |
| Published demonstration | Four synchronized mirrors |
| Demo actuation | Eight synchronized comb actuators per mirror |
| Configuration | Multiple actuators per mirror, one-to-one tiles, or hybrid pairing |
| Angle sensing | Optional for closed-loop control |
| Spectral options | Visible or infrared; coating selected for the application |
| Aperture, travel and thermal requirements | Configured for the application |